Figure 1 shows the appearance of C9410R.
 
Table 1 shows the Quick Specs.
| 
			 Feature  | 
			
			 Cisco Catalyst C9410R  | 
		
| 
			 Total number of slots  | 
			
			 10  | 
		
| 
			 Line-card slots  | 
			
			 8  | 
		
| 
			 Supervisor engine slots  | 
			
			 2  | 
		
| 
			 Dedicated supervisor engine slot numbers  | 
			
			 5 and 6  | 
		
| 
			 Supervisor engine redundancy  | 
			
			 Yes  | 
		
| 
			 Supervisor engines supported  | 
			
			 C9400-SUP-1, C9400-SUP-1XL, C9400-SUP-1XL-Y  | 
		
| 
			 Maximum PoE per slot  | 
			
			 2880W  | 
		
| 
			 Maximum Bandwidth scalability per line-card slot  | 
			
			 Up to 480 Gbps on all slots  | 
		
| 
			 Number of power supply bays  | 
			
			 8  | 
		
| 
			 AC input power  | 
			
			 Yes  | 
		
| 
			 Integrated PoE  | 
			
			 Yes  | 
		
| 
			 Power supplies supported  | 
			
			 3200W AC, 2100W AC  | 
		
| 
			 Number of fan-tray bays  | 
			
			 1  | 
		
| 
			 Location of 19-inch rack-mount  | 
			
			 Front  | 
		
| 
			 Dimensions (H x W x D)  | 
			
			 22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)  | 
		
| 
			 Rack Units (RU)  | 
			
			 13 RU  | 
		
| 
			 Chassis weight (with fan tray)  | 
			
			 65.0 lb (29.48 kg)  | 
		
| 
			 Mounting  | 
			
			 19-in. rack compatible (19-in. rack and cable guide hardware included)  | 
		
| 
			 Regulatory compliance  | 
			
			 22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)  | 
		
| 
			 Safety  | 
			
			 ● UL 60950-1 ● CAN/CSA-C222.2 No. 60950-1 ● EN 60950-1 ● IEC 60950-1 ● AS/NZS 60950.1 ● IEEE 802.3  | 
		
| 
			 EMC  | 
			
			 ● 47 CFR Part 15 ● CISPR22 Class A ● KN 32 Class A ● EN 300 386 V1.6.1 ● EN 55022 Class A ● EN 55032 Class A ● CISPR 32 Class A ● EN61000-3-2 ● EN61000-3-3 ● ICES-003 Class A ● TCVN 7189 Class A ● V-3 Class A ● CNS13438 Class A ● CISPR24 ● EN 300 386 ● EN55024 ● TCVN 7317 ● KN35  | 
		
| 
			 Industry EMC, safety, and environmental standard s  | 
			
			 ● NEBS: Operating temperature: -5 to 55C ● Relative Humidity: 10-93% ● Operating Altitude: up to 1829 m (6000 ft) at 55C ● ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations. ● SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue) ● ETS 300 019-2-1, Class 1.2 Storage ● ETS 300 019-2-2, Class 2.3 Transportation ● ETS 300 019-2-3, Class 3.2 Stationary ● EN50121-4 ● EN 300 386  | 
		
| 
			 ROHS compliance  | 
			
			 ROHS5  | 
		
			Cisco Catalyst C9410R Specification | 
		|
| 
			 Total number of slots  | 
			
			 10  | 
		
| 
			 Line-card slots  | 
			
			 8  | 
		
| 
			 Supervisor engine slots  | 
			
			 2  | 
		
| 
			 Dedicated supervisor engine slot numbers  | 
			
			 5 and 6  | 
		
| 
			 Supervisor engine redundancy  | 
			
			 Yes  | 
		
| 
			 Supervisor engines supported  | 
			
			 C9400-SUP-1, C9400-SUP-1XL, C9400-SUP-1XL-Y  | 
		
| 
			 Maximum PoE per slot  | 
			
			 2880W  | 
		
| 
			 Maximum Bandwidth scalability per line-card slot  | 
			
			 Up to 480 Gbps on all slots  | 
		
| 
			 Number of power supply bays  | 
			
			 8  | 
		
| 
			 AC input power  | 
			
			 Yes  | 
		
| 
			 Integrated PoE  | 
			
			 Yes  | 
		
| 
			 Power supplies supported  | 
			
			 3200W AC, 2100W AC  | 
		
| 
			 Number of fan-tray bays  | 
			
			 1  | 
		
| 
			 Location of 19-inch rack-mount  | 
			
			 Front  | 
		
| 
			 Dimensions (H x W x D)  | 
			
			 22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)  | 
		
| 
			 Rack Units (RU)  | 
			
			 13 RU  | 
		
| 
			 Chassis weight (with fan tray)  | 
			
			 65.0 lb (29.48 kg)  | 
		
| 
			 Mounting  | 
			
			 19-in. rack compatible (19-in. rack and cable guide hardware included)  | 
		
| 
			 Regulatory compliance  | 
			
			 22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)  | 
		
| 
			 Safety  | 
			
			 ● UL 60950-1 ● CAN/CSA-C222.2 No. 60950-1 ● EN 60950-1 ● IEC 60950-1 ● AS/NZS 60950.1 ● IEEE 802.3  | 
		
| 
			 EMC  | 
			
			 ● 47 CFR Part 15 ● CISPR22 Class A ● KN 32 Class A ● EN 300 386 V1.6.1 ● EN 55022 Class A ● EN 55032 Class A ● CISPR 32 Class A ● EN61000-3-2 ● EN61000-3-3 ● ICES-003 Class A ● TCVN 7189 Class A ● V-3 Class A ● CNS13438 Class A ● CISPR24 ● EN 300 386 ● EN55024 ● TCVN 7317 ● KN35  | 
		
| 
			 Industry EMC, safety, and environmental standards  | 
			
			 ● NEBS: Operating temperature: -5 to 55C ● Relative Humidity: 10-93% ● Operating Altitude: up to 1829 m (6000 ft) at 55C ● ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations. ● SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue) ● ETS 300 019-2-1, Class 1.2 Storage ● ETS 300 019-2-2, Class 2.3 Transportation ● ETS 300 019-2-3, Class 3.2 Stationary ● EN50121-4 ● EN 300 386  | 
		
| 
			 ROHS compliance  | 
			
			 ROHS5  |