As cloud computing applications are being widely adopted, the Wide Area Network (WAN) undergoes major changes to cope with these changes. Users are demanding more than they have traditionally expected from their routers. Faced with new challenges and opportunities, H3C has developed the MSR26/36/56 multi-service router based on its decade-long in-depth understanding of enterprise and carrier networks, as well as more than a decade’s insight and technical accumulation. MSR 26/36 can serve as access router for governments and financial institutions or core router for small size enterprise. The MSR56 can serve as a core router for small-medium sized enterprises, a gateway router for government branches or enterprises, or a service gateway for enterprise network VPNs, NAT or IPSec services. Along with other H3C network equipment, it provides a comprehensive network solution to users in multiple industries from government to financial institutions, hotels, enterprises and educational institutions.
Item |
MSR26-30 |
MSR36-10 |
MSR36-20 |
MSR36-40 |
MSR36-60 |
IPv4 Forwarding performance |
1.5Mpps |
5Mpps |
5Mpps |
6Mpps |
9Mpps |
IPv6 Forwarding performance |
1Mpps |
4Mpps |
4Mpps |
5Mpps |
7.5Mpps |
Forwarding performance in service (IMIX) |
800Mbps |
1.5Gbps |
1.5Gbps |
2Gbps |
3Gbps |
USB2.0 |
1, 3G Modemcompatible |
2, 3G Modemcompatible |
2, 3G Modemcompatible |
2, 3G Modemcompatible |
2, 3G Modemcompatible |
CON(Mini-USB Type AB) |
1 |
1 |
1 |
1 |
1 |
CON/ AUX |
1 |
1 |
1 |
1 |
1 |
Fixed GE port |
2 |
3(1Combo) |
3(1Combo) |
3(2Combo) |
3(2Combo) |
SIC slot |
3 |
2 |
4 |
4 |
4 |
DSIC slot |
1 |
- |
2 |
2 |
2 |
HMIM slot |
- |
1 |
2 |
4 |
6 |
DHMIM slot |
- |
- |
- |
- |
1 |
VPM |
- |
- |
1 |
2 |
2 |
Maximum power usage |
54W |
100W |
125W |
300W |
300W |
Redundant power supply |
- |
RPS800 |
RPS800 |
Internal configuration (AC/DC/PoE) |
Internal configuration (AC/DC/PoE) |
Power supply |
AC: 100V a.c.~240V a.c.;50Hz/60Hz |
AC: 100V a.c.~240V a.c.;50Hz/60Hz DC:-48~-60V |
AC: 100V a.c.~240V a.c.;50Hz/60Hz DC:-48~-60V |
AC/PoE: 100V a.c.~240V a.c.;50Hz/60Hz DC:-48~-60V |
AC/PoE: 100V a.c.~240V a.c.;50Hz/60Hz DC:-48~-60V |
Rack height (U Height) |
1 rack height (1RU) |
1 rack height (1RU) |
1 rack height (1RU) |
2 rack height (2RU) |
3 rack height (3RU) |
Dimensions (W×D×H) |
360×300×44.2mm |
440×480×44.2mm |
440×480×44.2mm |
440×480×88.1mm |
440×480×130.5mm |
Operating temperature |
0~45℃ |
||||
Operatinghumidity |
5~95% (non-condensing) |
||||
EMC |
FCC Part 15 (CFR 47) CLASS A ICES-003 CLASS A VCCI-3 CLASS A VCCI-4 CLASS A CISPR 22 CLASS A EN 55022 CLASS A AS/NZS CISPR22 CLASS A CISPR 24 EN 55024 EN 61000-3-2 EN 61000-3-3 EN 61000-6-1 ETSI EN 300 386 EN 301 489-1 EN 301 489-17 |
||||
Security |
UL 60950-1 CAN/CSA C22.2 No 60950-1 IEC 60950-1 EN 60950-1/A11 AS/NZS 60950 EN 60825-1 EN 60825-2 FDA 21 CFR Subchapter J GB 4943 |