LEDs |
Represents |
Color |
Description |
PSU |
Power Supply Unit (P0 and P1) Status |
Green |
PSU is on and is providing power. |
Amber |
PSU is on but with errors or in a failure condition. |
||
Off |
Power supply is turned off. |
||
GE POE |
Internal PoE Daughter Card Status |
Green |
PSU is installed and providing power |
Amber |
PSU is installed but in a failure condition. |
||
Off |
PSU is off. |
||
FLASH |
System Flash Status |
Blinking Green |
Compact flash/eUSB flash is present and currently being accessed. |
TEMP |
Temperature Status |
Solid green |
All temperature sensors in the system are within acceptable range. |
Amber |
One or more temperature sensors in the system are outside the acceptable range. |
||
Off |
Temperature is not being monitored. |
||
PWR |
System Power |
Green |
System power is on and functioning correctly. |
Green blinking |
System power is in the process of shutting down. |
||
Amber |
System power is up, but low level initialization failed. |
||
Amber blinking |
System power is up, but the system failed to come out of reset. |
||
Off |
System power is off. |
||
POE BOOST |
Power Over Ethernet Boost Mode |
Green |
Two PoE power supplies are installed and operating in boost mode. |
Off |
This can mean one of the following: ·No PoE PSU installed. ·One PoE PSU installed. ·Two PoE PSUs installed and operating in redundant mode. |
||
ISC |
ISC Slot Status |
Green |
PVDM4 is present and enabled. |
Amber |
Initialized with error. |
||
Off |
Not present. |
||
FAN |
Fan Status |
Green |
All fans are operating. |
Amber |
One fan has stopped working. |
||
Blinking Amber |
Two or more fans have stopped working, or the fan tray has been removed. |
||
Off |
Fans are not being monitored. |
||
STAT |
System Status |
Solid green |
System operating normally. |
Blinking amber |
BIOS/Rommon is booting. |
||
Amber |
BIOS/Rommon has completed booting, and system is at Rommon prompt or booting platform software. |
||
Off |
System is not out of reset or BIOS image is not loadable. |
Figure 3 shows the back panel of Cisco ISR4451-X-V/K9.
Note:
① |
USB Type A port |
⑤ |
Auxiliary port |
② |
GE management port |
⑥ |
GE Ports |
③ |
USB Type B mini port |
⑦ |
NIM Slots |
④ |
Console port |
⑧ |
SM-X Slot |
Cisco ISR4451-X-V/K9 Specification |
|
Product Number |
ISR4451-X-V/K9 |
Product Description |
Cisco ISR 4451 UC Bundle. PVDM4-64. UC Lic. CUBE25 |
Aggregate Throughput |
1 Gbps to 2Gbps |
Total onboard WAN or LAN 10/100/1000 ports |
4 |
RJ-45-based ports |
4 |
SFP-based ports |
4 |
Enhanced service-module slots |
2 |
Doublewide service-module slots |
1 (assumes no singlewide SM-X modules installed) |
NIM slots |
3 |
OIR (all I/O modules) |
Yes |
Onboard ISC slot |
1 |
Default memory double-data-rate 3 (DDR3) error-correction-code (ECC) DRAM (Combined control/services/data planes) |
NA |
Maximum memory DDR3 ECC DRAM (Combined control/services/data planes) |
NA |
Default memory DDR3 ECC DRAM (data plane) |
2 GB |
Maximum memory DDR3 ECC DRAM (data plane) |
2 GB |
Default memory DDR3 ECC DRAM (control/services plane) |
4 GB |
Maximum memory DDR3 ECC DRAM (control/services plane) |
16 GB |
Default flash memory |
8 GB |
Maximum flash memory |
32 GB |
External USB 2.0 slots (type A) |
2 |
USB console port -type B mini (up to 115.2 kbps) |
1 |
Serial console port - RJ45 (up to 115.2 kbps) |
1 |
Serial auxiliary port - RJ45 (up to 115.2 kbps) |
1 |
Power-supply options |
Internal: AC, DC and PoE |
Redundant power supply |
Internal: AC, DC and PoE |
AC input voltage |
100 to 240 VAC autoranging |
AC input frequency |
47 to 63 Hz |
AC input current range, AC power supply (maximum) |
7.1 to 3.0A |
AC input surge current |
<50 A |
Typical power (no modules) (watts) |
158 |
Maximum power with AC power supply (watts) |
450 (no PoE) |
Maximum power with PoE power supply (platform only) (watts) |
1000 with PoE redundant 1450 with PoE boost no redundancy |
Maximum endpoint PoE power available from PoE power supply (watts) |
500 W with optional redundancy |
Maximum endpoint PoE power capacity with PoE boost (watts) |
950 W no redundancy |